waste water sampler
The 6712 Portable Sampler features a vacuum-formed ABS plastic shell to withstand exposure and abuse. Its tapered design and trim 50.8 cm diameter result in easy manhole installation and removal. Large, comfortable handles make transporting safe and convenient - even when wearing gloves. The IP67 enclosure is submersible, watertight, and dust-tight. Plug-in 700 Series Modules and the new SDI-12 interface make it easy to add flow and parameter monitoring to your 6712-based system. Isco's advanced 6712 Controller allows you to select different programming modes to assure the most suitable routine for your application. Programming is fast and simple, with on-line help just a key stroke away.
Standard Features
  • New SDI-12 interface provides “plug and play” connection with compatible measuring devices - including multi-parameter sondes from leading manufacturers.
  • Standard 4MB of memory gives you great flexibility for logging environmental data.
  • Choice of 11 different glass and plastic bottle configurations ranging from 24 x 1liter to 1 x 5.5 gallon.
  • IP67 controller enclosure
  • Rugged ABS plastic shell
  • Foam-insulated base holds up to 13.5 kg of ice, preserving samples for extended periods, even in extreme conditions.
  • Sample delivery at the EA-recommended velocity of 0.5m/sec., even at head heights of 8m.
  • Patented pump revolution counter ensures accurate sample volumes - and tells you when tubing should be replaced.
Applications
Portable sampling in industrial and municipal applications where explosion hazard reduction required.
Options and Accessories
  • Composite sampling bottle configurations
  • Sequential sampling bottle configurations
  • ProPak disposable sample bags
  • Suction lines and strainers
  • Power sources including Ni-cad or lead-acid batteries and solar panels
  • 674 Rain Gauge
  • 700 Series Modules for flow and parameter measurement
  • Telephone Modem
  • Cell phone-based data retrieval and dial-out alarm
  • Wireless radio data retrieval with 2102 module
  • 581 RTD data retrieval device
  • Flowlink® Software
  • Optional temperature sensor - provides precise log of sample compartment temperature for automatic documentation
Specifications 6712 Full-Size Portable Sampler
  • Size (Diam x Ht): 68.6 x 50.7 cm
  • Weight: Dry, Less Battery - 15 kg
  • Material: Fiberglass-reinforced plastic with UV-resistant gel coat
    Power Requirements: 12 VDC
  • Pump
    • Intake purge: Adjustable air purge before and after each sample.
    • Tubing life indicator: Provides a warning to change pump tubing.
      Intake suction tubing: Vinyl or Teflon®; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length
    • Pump tubing life: Typically 1,000,000 pump counts
      Maximum lift: 28 feet (8.5 m)
    • Repeatability: Typical ±5 ml or ±5% of the average volume in a set
    • Typical line velocity @ Head height: 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m)
  • Liquid presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.
  • Controller
    • Weight: 13 lbs. (5.9 kg)
    • Size (HxWxD): 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm)
    • Operational temperature: 32° to 120°F (0° to 49°C)
    • Enclosure rating: NEMA 4X, 6 IP67
    • Program memory: Non-volatile ROM
    • Flow meter signal input: 5 to 15 volt DC pulse or 25 millisecond isolated contact closure.
    • Number of composite samples: Programmable from 1 to 999 samples
    • Clock Accuracy: 1 minute per month, typical, for real time clock
  • Software
    • Sample frequency: 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses
    • Sampling modes: Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.)
    • Programmable sample volumes: 10 to 9,990 ml in 1 ml increments
      Sample retries: If no sample is detected, up to 3 attempts; user selectable
    • Rinse cycles: Automatic rinsing of suction line up to 3 rinses for each sample collection
    • Program storage: 5 sampling programs
    • Sampling Stop/Resume: Up to 24 real time/date sample stop/resume commands
    • Controller diagnostics: Tests for RAM, ROM, pump display, and distributor

|
|
|
|
|
|
|
|
|
|
|
|
|
|

© Envitech Ltd: 2005
 

 

For Hire equipment, please visit our hire page.

Latest news!

Yorkshire Water FRAMEWORK

Envitech’s Technical Director,
Jim Pickering and Angela
Spence, Yorkshire Water’s
Senior Buyer sign the Framework Agreement for the design,
supply, installation, training & commissioning of Instrumentation for the Environmental Business unit.


NEW AmNiSys ANALYSER

ISE probe for Ammonium and Nitrate

Envitech offer a new probe for measuring Ammonium and Nitrate in Waste Water featuring Automatic compensation for residual interferences - click here for more details


ATEX SAMPLER

Envitech are able to offer the ORI 'Basic mobil Ex 1' Atex-approved sampler for hazardous locations. Please contact us for more information, or visit the relevant web-page.


Pause
Resume