Process Buoy PBS1 for NH4 measurement..
- measure ammonia directly in the sample
..
The Process Buoy PBS 1 measures ammonium through direct immersion in aeration basins or final effluent. The buoy is filled by the hydrostatic pressure of the water, and emptied by air pressure. This eliminates the need for pumps in the wastewater. Valves contact only air, reagents, and calibration standards, assuring a high level of reliability.
For ammonia measurement the STIP Process Buoy PBS 1 (NH4) is equipped with a purgeable cell, in which wastewater is separated from sludge and solids before it is fed into the reaction cell. During the ammonium measurement, the necessary pH value is accurately regulated to assure high measuring accuracy with low reagent consumption. The buoy automatically calibrates itself daily using the standard addition method, and at the same time compensates for variability in the wastewater.
Standard Features
  • Measurement directly in aeration basins
  • Automatic self-calibration using standard addition method
  • Measuring range: 0.1 - 50 mg/liter NH4 - N
  • Analysis delay time: 5 minutes
  • No sample preparation, pumps, or transfer lines
  • 6-hour on-screen graph, scrollable through 14 days
  • 90 day data storage on diskette
  • Programmable concentration alarms
Applications
  • Aeration basins
  • Final effluent

List of articles - nutrient monitoring applications

Options and Accessories
  • Freeze protection cap for Process Buoy
  • Baffles for mounting in quiet zone in turbulent water
Specifications of Process Buoy PBS1 NH4 analyser

NH4 Measurement

  • Measuring ranges (mg/L NH4 – N): 0.1 – 3; 0.25 – 8; 1-25; 4 - >25
  • Detection Limit: 0.1 mg/L
  • Reproducibility: 3%
  • Reagent consumption: 1 liter/month
  • T90 time: 3 - 5 minutes

Electrical and standards conformity

  • Buoy power: 15/24 V from controller
  • Mains power: 115 VAC/50 Hz or 60 Hz
  • Average current: 0.3 A @ 115 VAC, , 0.15 A @ 230 VAC for single buoy system; 0.4 A/0.2 A for dual-buoy system
  • Maximum current: 0.4 A @ 115 VAC, , 0.2 A @ 230 VAC for single buoy system; 0.6 A/0.3 A for dual-buoy system
  • Power load: 45 W for single buoy; 68 W for dual buoy
  • Enclosure: IP65
  • Protection class: 1 (per IEC 4010)
  • Immunity to voltage change: EN 50022
  • EMC emission: EN 50081-1, 12/96
  • EMC noise immunity: EN 50082-2, 12/96
  • Certification: CE Mark (Declaration of conformity)
  • Test method: per DIN/VDE 0701

Dimensions and weights:

  • Process Buoy: 830 x 130mm (length x diameter); approx. 10.8 kg (filled)
  • Controller, single-buoy: 264 x 360 x 345 mm (W x H x D); 12.0 kg
  • Controller, double-buoy: 360 x 400 x 345 mm; 14.0 kg

Data display, inputs and outputs

  • Display: LCD graphics display, 16 lines by 40 characters, backlit
    Keypad: 21 key, 13 x 13 mm
  • Data presentation: 6-hour graph (14-day scrollable); current value with 5-digit resolution
  • Data storage: 10 days in RAM; 90 days with diskette drive (data interval 2 minutes)
  • Logging of warnings, malfunctions, limit value alarms and calibrations for last 4 weeks (90 days with diskette drive), alerts for leakage, defective probe, general error for outside of measuring range
  • Analog outputs: 0 - 20 mA or 4 - 20 mA selectable, electrically isolated load max 500 ohm
  • Limit value alarms: Dry contact relay (normally closed) for high limit, low limit, and slope
  • Diskette drive: PC-compatible 3.5" diskette drive for data storage
    Computer interface: RS 232C for data output and remote control

|
|
|
|
|
|
|
|
|
|
|
|
|
|

© Envitech Ltd: 2005
 

 


Point to see video of first UK In-situ ammonia monitor PBS1