PORTABLE
AUTOMATIC WATER & WASTEWATER SAMPLERS..
|
 |
The
ORI Basic mobil Ex 1 Sampler
is designed for hazardous location installation
and meets the IEC (International Electrotechnical Commission)
standards for Zone 1 operation. It provides users with a viable
alternative to manual sample collection in hazardous locations.
The Zone 1approval is by TUV, an internationally recognized
testing lab.
The ATEX rating is achieved using specialized batteries and
a cast aluminum case that contains the controller components.
In addition, a unique programming interface eliminates the
need for keypad entry of program parameters, and serves to
maintain the operational safety required for Zone 1 &
2 applications.
|
|
Basic
mobil Ex 1 Zone 1 sampler
- portable intrinsically safe sampler for hazardous locations
|
|
Standard
Features
|
- TUV-approved
to IEC Standards for Zone 1 locations
- Compact
size (41 cm diameter) fits into small manholes.
- Stores
up to 10 different programs which can be initiated at the
press of a button
- Peristaltic
pump delivers accurate sample volumes at head heights up
to 20 feet
- Includes
protective cover for NEMA 4 (IP56) enclosure rating
- Automatic
calculation of optimal fill volume
- Automatic
error check
- Status
check can be performed anytime during operation
|
|
Applications
|
| Portable
sampling in industrial and municipal applications where explosion
hazard reduction required. |
|
Options
and Accessories
|
|
- Multi-bottle
sampling configurations - 12/24 bottles, 500ml and 1000ml
PE or glass bottles
- Single-bottle
sampling configuration - 1 x 13 liter plastic bottle
- Zone
1 Battery (10 Amp-hour or 20 Amp-hour)
- Battery
Charger.
- Suction
lines and strainers
|
|
Specifications
|
- Zone
1 explosion-proof portable sampler
- Height:
28 in (71 cm)
- Diameter:
16.25 in. (41 cm)
- Weight
(dry): 55 lbs. (24 kg)
- Cooling
Capacity: 10 lbs (5 kg) crushed ice
- Power
Requirements: 12 volts DC. (Supplied by battery or AC adapter)
- Intake
Suction Tubing: 0.31 in (8 mm) Vinyl or Teflon-lined; Max
length: 65 ft (20 m)
- Maximum
Suction Lift: 20 ft (6 m)
- Standby
Power Drain: 45 mA
- Flow
Pacing: 4-20 mA or dry 50 ms contact closure
- Program
Delay: 1 minute to 199 hrs, 59 minutes
- Data
Log: Up to 50 sample events and errors
- Sample
Volume: Automatically calculated based on program and bottle
setting
- Electrical
Safety Rating: Zone 1& 2 approved
- Controller:
IP65, EExd (ib) IIB T6 for zones 1 & 2 Explosion-protected
Battery: EEx de IIC T6 for zones 1 & 2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
©
Envitech Ltd: 2005
|
|