PORTABLE AUTOMATIC WATER & WASTEWATER SAMPLERS..
explosion-proof sampler
The ORI Basic mobil Ex 1 Sampler is designed for hazardous location installation and meets the IEC (International Electrotechnical Commission) standards for Zone 1 operation. It provides users with a viable alternative to manual sample collection in hazardous locations. The Zone 1approval is by TUV, an internationally recognized testing lab.

The ATEX rating is achieved using specialized batteries and a cast aluminum case that contains the controller components. In addition, a unique programming interface eliminates the need for keypad entry of program parameters, and serves to maintain the operational safety required for Zone 1 & 2 applications.

Basic mobil Ex 1 Zone 1 sampler
- portable intrinsically safe sampler for hazardous locations
Standard Features
  • TUV-approved to IEC Standards for Zone 1 locations
  • Compact size (41 cm diameter) fits into small manholes.
  • Stores up to 10 different programs which can be initiated at the press of a button
  • Peristaltic pump delivers accurate sample volumes at head heights up to 20 feet
  • Includes protective cover for NEMA 4 (IP56) enclosure rating
  • Automatic calculation of optimal fill volume
  • Automatic error check
  • Status check can be performed anytime during operation
Applications
Portable sampling in industrial and municipal applications where explosion hazard reduction required.
Options and Accessories
  • Multi-bottle sampling configurations - 12/24 bottles, 500ml and 1000ml PE or glass bottles
  • Single-bottle sampling configuration - 1 x 13 liter plastic bottle
  • Zone 1 Battery (10 Amp-hour or 20 Amp-hour)
  • Battery Charger.
  • Suction lines and strainers
Specifications
  • Zone 1 explosion-proof portable sampler
  • Height: 28 in (71 cm)
  • Diameter: 16.25 in. (41 cm)
  • Weight (dry): 55 lbs. (24 kg)
  • Cooling Capacity: 10 lbs (5 kg) crushed ice
  • Power Requirements: 12 volts DC. (Supplied by battery or AC adapter)
  • Intake Suction Tubing: 0.31 in (8 mm) Vinyl or Teflon-lined; Max length: 65 ft (20 m)
  • Maximum Suction Lift: 20 ft (6 m)
  • Standby Power Drain: 45 mA
  • Flow Pacing: 4-20 mA or dry 50 ms contact closure
  • Program Delay: 1 minute to 199 hrs, 59 minutes
  • Data Log: Up to 50 sample events and errors
  • Sample Volume: Automatically calculated based on program and bottle setting
  • Electrical Safety Rating: Zone 1& 2 approved
  • Controller: IP65, EExd (ib) IIB T6 for zones 1 & 2 Explosion-protected
    Battery: EEx de IIC T6 for zones 1 & 2

 

Sampsys_P_EX portable ATEX sampler

ATEX sampler with battery

ATEX sampler display

ATEX sampler protective cover

Zone 1 sampler