| |
|
ISCO
2150 FLOWLOGGER..
|
|
|
NEW
- Atex Zone 0 version available now!
The 2150 Flow Module combines Isco's proven area velocity flow measurement
with the flexibility and versatility of a unique modular design.
The 2150 is a field-configurable measurement and data storage system
in a compact, sealed enclosure. The 2150 and companion 2100 Series
Modules are powered by the 2191 Battery Module, which holds 2 standard
alkaline or rechargeable lead-acid lantern batteries. Highly efficient
power management provides battery life up to 15 months

GSM
modem option
|
|
The
2150 Area Velocity sensor mounts at the bottom of the channel and
uses Doppler technology to directly measure average velocity in
the flow stream. An integral pressure transducer measures liquid
depth to determine flow area, and flow rate is calculated by multiplying
the area of the flow stream by its average velocity. Isco's Doppler
system continuously senses the velocity profile of the flow stream,
eliminating the manual profiling and calibration required by electromagnetic
systems.
The area velocity
method gives you greater accuracy where weirs and flumes are not
practical, and where submerged, full pipe, surcharged and reverse
flow conditions may occur. You don't have to estimate the slope
and roughness of the channel, and "silt correction" compensates
for debris that accumulates on the bottom of the channel.
Isco
Flowlink 4 Software (v. 4.1 or higher) is used to set up 2150
Flow Modules, and to retrieve and analyze stored data.
|
2108
ANALOG OUTPUT MODULE FOR 2150 |
 |
The 2108
Output Module provides three independent current outputs for
Isco 2100 Series Area Velocity Flow modules; the 2150, 2151,
and 2151P. The 2108 is DIN Rail mounted and uses a 7-26V DC
power supply.
It provides
an easy interface from Iscos advanced 2100 Series Area
Velocity Modules to data collection systems like SCADA/DCS
or any other secondary instrument systems.
Standard
Features
- Three
independent, isolated outputs per module.
- Outputs
are freely programmable for any parameter measured by Iscos
Area Velocity flow module.
- When
more than one module is stacked, each output can be configured
for any parameter for any module connected to the 2108.
- The
2108 Module can be mounted as far as 3,000 ft from other
modules (an Isco Quick Disconnect is recommended to simplify
the installation).
- Isco
Flowlink 4.15 can interrogate any 2100 Series module through
the 2108, eliminating the need for confined space entry.
Specifications
|
|
|
2150
Flow Module Standard Features |
- Up to one
year battery life. Battery voltage readout lets you know when
to change batteries.
- Sealed, submersible
enclosure meets NEMA 4X, 6P and IP68 requirements
- Easy to upgrade.
New operating software can be downloaded into non-volatile "flash"
memory via PC connection, without affecting stored program and
data.
- Measure shallow
flows in small pipes. The low profile Area Velocity sensor minimizes
flow stream obstruction and senses velocity in flows down to 1
inch (25 mm) in depth.
- Chemically
resistant. The epoxy-encapsulated sensor withstands tough applications.
- Rollover
memory with variable rate data storage, lets you change the data
storage interval when programmed conditions occur.
- Pressure
transducer venting system automatically compensates for changes
in atmospheric pressure to maintain accuracy
- Quick connect
area velocity sensor can be easily removed and interchanged in
the field with no recalibration.
- High-capacity
internal desiccant cartridge keeps the vent free of moisture during
normal operation
- Replaceable
hydrophobic filter protects against intrusion of water during
submersion.
- Sealed AV
sensor resists fouling by oil and grease, eliminating frequent
cleanings needed withelectromagnetic probes.
- 38.4k baud
communication provides speedy setup and data retrieval.
|
|
Applications
|
- Stack modules
you need to build a compact, integrated system.
- Monitor multiple
flow streams at the same time.
- Obtain redundant
measurements to guarantee integrity.
- Remotely
locate modules and connect them via cable.
- Expand your
monitoring system as your requirements evolve
|
|
Options
and Accessories
|
|
- 2101 Field
Wizard - ruggedized keyboard and display stacks on 2100 system
- 2102 Wireless
Module - adds 2-way spread spectrum radio communication for remote
data retrieval without manhole entry
- 2103
Modem Module - adds telephone (land line) communication for
remote data retrieval
|
|
Specifications
of 2150 Isco Flowmeter
|
- Size (H x
W x D): 2.9 x 11.3 x 7.5 in. (7.4 x 28.7 x 19.1 cm)
- Weight: 2.0
lbs. 0.9 kg
- Material:
High-impact molded polystyrene
- Enclosure:
NEMA 4X, 6P IP68 (self-certified)
- Power: 6.6
to 16.6V DC, 100 mA typical at 12V DC, 1 mA standby
Typical Battery
Life, for given data storage interval and 2 batteries of indicated
type
- 15 minute
interval: 15 months (alkaline batteries); 2½ months (lead-acid
batteries)
- 5 minute
interval: 8 months (alkaline batteries); 1½ months (lead-acid
batteries)
- 1 minute
interval: 2 months (alkaline batteries); 11 days (lead-acid batteries)
- Program Memory:
Non-volatile, programmable flash; can be updated using PC without
opening enclosure; retains user program after updating
- Number of
Modules: Up to 4, field interchangeable
Maximum Distance Between Modules: 3300 ft (1000 m)
- Wiring Between
Remote Modules: Twisted pair for communication, pair for power,
gauge dependent on distance
- Flow Rate
Conversions: Up to 2 independent level-to-area conversions
and/or level-to-flow rate conversions
Level-to-Area
Conversions
- Channel Shapes:
Round, U-shaped, rectangular, trapezoidal, elliptical, with silt
correction
- Data Points:
Up to 50 level-area points
Level-to-Flow
Rate Conversions
Area Velocity
Sensor
- Size (H x
W x L): 0.75 x 1.31 x 6.00 in. (1.9 x 3.3 x 15.2 cm)
- Cable Length:
25 ft. (7.6 m)
- Cable Diameter:
0.37 in. 0.9 cm
- Weight (including
cable): 2.1 lbs. 0.95 kg
- Materials:
Sensor - Epoxy, chlorinated polyvinyl chloride (CPVC), stainless
steel; Cable - Polyvinyl chloride (PVC), chlorinated polyvinyl
chloride (CPVC).
Level Measurement
method:
- Submerged
pressure transducer mounted in the flow stream.
- Transducer
Type: Differential linear integrated circuit pressure transducer
- Range: 0.033
to 10 ft (0.010 to 3.05 m)
- Maximum Allowable
Level: 20 ft. (6.1 m)
- Accuracy
- non-linearity and hysteresis at 77°F (25°C) per foot
of change from calibration depth, for indicated level range
0.033 to 5.0 ft (0.03 to 1.52 m): ±0.008 ft/ft (±0.008
m/m)
Greater than 5.0 ft (1.52 m): ±0.012 ft/ft (±0.012
m/m)
Maximum Long-Term Drift: 0.033 ft. (0.010 m)
Temperature Coefficient: ±0.0035 ft/°F (±0.0019
m/°C) (Max error within compensated range, per degree of change
from calibration temperature.)
Velocity
Measurement method:
- Method: Doppler
ultrasonic, Frequency 500 kHz, Transmission Angle 20° from
horizontal
- Typical Minimum
Depth: 1 inch (25 mm)
- Range: -5
to +20 ft/s (-1.5 to +6.1 m/s)
- Accuracy
- in water, uniform velocity, speed of sound = 1480 m/s, for indicated
velocity range
-5 to +5 ft/s (-1.5 to +1.5 m/s): ±0.1 ft./s (±0.03
m/s)
5 to 20 ft/s (1.5 to 6.1 m/s): ±2% of reading
- Operating
Temperature: 32° to 160°F (0° to 71°C)
- Compensated
Range: 32° to 122°F (0° to 50°C)
2191 Battery
Module
- Size (H x
W x D): 6.0 x 9.6 x 7.6 in (15.2 x 24.4 x 19.3 cm)
- Weight (without
batteries): 3.2 lbs (1.4 kg)
- Material:
High-impact molded polystyrene
- Enclosure:
NEMA 4X, 6P IP68 (self-certified)
- Batteries:
6V alkaline lantern or lead-acid lantern, quantity 2
- Capacity:
Alkaline Lantern Batteries - 25 Ahrs; Lead-Acid Lantern Batteries
- 5 Ahrs
|
|
|
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
|
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
|
|
© Envitech
Ltd: 2005 |
|
|